[{"caption":"Concrete slab systems: support comes first","columns":[{"key":"system","label":"What the name means","source_line":"ACI, HUD (1999), NOAA, CRSI and PCI; read 2026-11-09. Each row is bound to its source in the downloads."},{"key":"drawing","label":"What the proposal should show","source_line":"Editorial scope advice based on those captured system descriptions; read 2026-11-09."}],"rows":[{"option":"ground-supported","label":"Slab on grade: monolithic or stem-wall foundation","cells":{"system":{"text":"Floor supported by soil; a monolithic foundation combines the floor and footing pour, while a stem-wall floor is poured afterward.","facts":["ground","monolithic","stemwall"]},"drawing":{"text":"Confirm the base, reinforcement, foundation sequence and thickened areas.","facts":["ground","monolithic","stemwall"]}}},{"option":"frost-protected","label":"Frost-protected shallow foundation","cells":{"system":{"text":"Insulation changes the frost-protection detail of a shallow foundation; NOAA describes depths as shallow as 16 inches.","facts":["fpsf-depth","fpsf-climate"]},"drawing":{"text":"Ask for the site-specific insulation and foundation-depth design, separately from slab thickness.","facts":["fpsf-depth","fpsf-climate"]}}},{"option":"one-way","label":"One-way slab and beam","cells":{"system":{"text":"The floor transfers loads to beams and then columns.","facts":["one-way","suspended"]},"drawing":{"text":"Have the plan identify the beam and column load path.","facts":["one-way","suspended"]}}},{"option":"flat-plate","label":"Two-way flat plate","cells":{"system":{"text":"A two-way reinforced floor has no beams between columns.","facts":["plate","suspended"]},"drawing":{"text":"Locate columns and review the reinforcement and connection design.","facts":["plate","suspended"]}}},{"option":"two-way-beams","label":"Two-way slab with beams","cells":{"system":{"text":"Joists act as small beams within this floor system.","facts":["two-way","suspended"]},"drawing":{"text":"Compare the supporting members and the slab section on the structural drawing.","facts":["two-way","suspended"]}}},{"option":"drop-panels","label":"Two-way flat slab with drop panels","cells":{"system":{"text":"Added slab thickness around columns strengthens the column-floor connection.","facts":["drops","suspended"]},"drawing":{"text":"Locate the drop panels and account for the thicker zones in the floor section.","facts":["drops","suspended"]}}},{"option":"joist","label":"One-way joist / wide module","cells":{"system":{"text":"A one-way wide-module joist variation provides depth for stiffness and accommodates penetrations.","facts":["joist","suspended"]},"drawing":{"text":"Coordinate floor openings and service routes with the joist layout.","facts":["joist","suspended"]}}},{"option":"waffle","label":"Waffle slab / two-way pan joist","cells":{"system":{"text":"Joists run in both directions under a waffle slab.","facts":["waffle","suspended"]},"drawing":{"text":"Compare the rib grid, supports and floor penetrations before choosing the section.","facts":["waffle","suspended"]}}},{"option":"voided","label":"Voided flat plate","cells":{"system":{"text":"Voids remove concrete from areas where it is not needed to resist load.","facts":["voided","suspended"]},"drawing":{"text":"Require the structural layout of voided and solid zones.","facts":["voided","suspended"]}}},{"option":"hollowcore","label":"Precast hollowcore slab","cells":{"system":{"text":"Precast hollowcore components serve floor and roof decks, including residential buildings.","facts":["hollowcore-use","hollowcore-depth"]},"drawing":{"text":"Compare component depth, supports, connections and the planned openings.","facts":["hollowcore-use","hollowcore-depth"]}}}]},{"caption":"Read the dimensions in their proper scope","columns":[{"key":"value","label":"Sourced dimension or construction criterion","source_line":"HUD 1999, NOAA, PCI Gulf South and NRMCA CIP 6 (2014); read 2026-11-09. Not a project design or code minimum."}],"rows":[{"option":"ground-supported-0","label":"Typical residential slab thickness","cells":{"value":{"text":"Approximately 4 inches in HUD’s 1999 slab-on-grade example; not a universal design thickness.","facts":["slab-four"]}}},{"option":"frost-protected-1","label":"FPSF foundation depth","cells":{"value":{"text":"As shallow as 16 inches in NOAA’s guidance; depth is distinct from slab thickness.","facts":["fpsf-depth"]}}},{"option":"hollowcore-2","label":"Typical hollowcore component depths","cells":{"value":{"text":"6, 8, 10, 12, 15 and 16 inches, as listed by PCI Gulf South; project design determines the choice.","facts":["hollowcore-depth"]}}},{"option":"ground-supported-3","label":"Ground-slab joint spacing","cells":{"value":{"text":"CIP 6: 24 to 36 times slab thickness; further recommended maximum 15 feet.","facts":["joint-spacing","joint-limit"]}}},{"option":"ground-supported-4","label":"Ground-slab panel geometry","cells":{"value":{"text":"CIP 6: length no more than 1.5 times width; panels square or nearly square.","facts":["panel-ratio"]}}},{"option":"ground-supported-5","label":"Contraction groove depth","cells":{"value":{"text":"CIP 6: at least ¼ slab thickness, and not less than 1 inch.","facts":["joint-depth"]}}},{"option":"ground-supported-6","label":"Conventional saw-cut timing","cells":{"value":{"text":"CIP 6: within 4 to 12 hours after finishing; not a homeowner upkeep interval.","facts":["saw-timing"]}}}]}]