[{"caption":"What are hardie boards used for?","columns":[{"key":"profile","label":"Pattern and catalog dimension","source_line":"James Hardie product catalog, undated, read 2026-11-09; Reveal manual effective September 2018, read 2026-11-12."},{"key":"scope","label":"Detail to specify with that style","source_line":"Manufacturer catalog and DOE PNNL, read 2026-11-09; historical Reveal manual, read 2026-11-12."}],"rows":[{"option":"lap","label":"Hardie Plank lap siding","cells":{"profile":{"text":"Horizontal plank; catalog thickness 5/16 inch.","facts":["H1"]},"scope":{"text":"Name the plank finish and flashing at board ends and wall transitions.","facts":["H1","D7"]}}},{"option":"panel","label":"Hardie Panel and trim battens","cells":{"profile":{"text":"Panels with Hardie Trim Batten create the board-and-batten look. Stucco panel example: 5/16 inch thick.","facts":["H8","H2"]},"scope":{"text":"Specify panel texture, batten layout and flashing; panel width is not batten spacing.","facts":["H8","D7"]}}},{"option":"shingle","label":"Hardie Shingle","cells":{"profile":{"text":"Straight-edge shingle panel example: 1/4 inch thick.","facts":["H3"]},"scope":{"text":"Name the actual shingle panel and edge pattern; show transitions into other siding.","facts":["H3","D7"]}}},{"option":"artisan","label":"Hardie Artisan","cells":{"profile":{"text":"Artisan profiles have 5/8-inch thickness; the catalog describes mitered-corner flexibility.","facts":["H4"]},"scope":{"text":"Catalog finish is primed and smooth. Include the painting system in the scope.","facts":["H6"]}}},{"option":"architectural","label":"Hardie Architectural Panel","cells":{"profile":{"text":"Architectural Panel Fine Sand example: 5/16 inch thick.","facts":["H5"]},"scope":{"text":"Architectural Panel comes primed; distinguish panel-joint and edge details from a batten layout.","facts":["H9","D7"]}}},{"option":"reveal","label":"Reveal Panel System (2018 manual)","cells":{"profile":{"text":"Expressed joints; the 2018 manual describes vertical, horizontal and brick-pattern layouts.","facts":["H10","H11"]},"scope":{"text":"Distinguish this historical system and its exposed or countersunk fastening from Architectural Panel; identify the exact panel and trim system in the proposal.","facts":["H10","H11"]}}}]},{"caption":"How long should hardie board siding last?","columns":[{"key":"figure","label":"Sourced figure","source_line":"HUD CNA and DOE PNNL, undated; read 2026-11-09."},{"key":"meaning","label":"Scope and limitation","source_line":"HUD and DOE PNNL, undated; read 2026-11-09."}],"rows":[{"option":"planning","label":"Cement-board category","cells":{"figure":{"text":"45 years in both HUD Family and Elderly columns.","facts":["L1"]},"meaning":{"text":"Undated multifamily CNA row 3.3.3.1.3; no separate life estimate for these styles and no warranty-derived prediction.","facts":["L1"]}}},{"option":"rain","label":"Rainfall threshold","cells":{"figure":{"text":"40 inches or more annual rainfall.","facts":["D1"]},"meaning":{"text":"PNNL reports BEMMI recommends a rainscreen regardless of cladding at this threshold. Guidance, not a local code mandate.","facts":["D1"]}}},{"option":"fire","label":"Generic flame spread","cells":{"figure":{"text":"0, Class I in PNNL’s fiber-cement material table.","facts":["P1"]},"meaning":{"text":"PNNL names ASTM E-84 surface-burning testing. An hourly fire rating for a wall is a separate matter.","facts":["P2","P1"]}}},{"option":"coast","label":"Coastal fasteners","cells":{"figure":{"text":"Within 3,000 feet of ocean shoreline.","facts":["D5"]},"meaning":{"text":"PNNL advises stainless steel fasteners in this exposure; match the selected product’s attachment instructions.","facts":["D5"]}}}]}]