[{"caption":"What type of surge protector do I need?","columns":[{"key":"place","label":"Where it belongs","source_line":"NEMA and UL Solutions, undated; NIST historical guide (2001); read 2026-11-09."},{"key":"selection","label":"What to specify","source_line":"NEMA and UL Solutions, undated; NIST historical guide (2001); read 2026-11-09."},{"key":"life","label":"Life evidence","source_line":"NEMA and UL Solutions, undated; NIST historical guide (2001); read 2026-11-09."}],"rows":[{"option":"type-1","label":"Type 1 service-entrance SPD","cells":{"place":{"text":"Permanently connected at the service entrance; Type 1 can also be installed on the load side.","facts":["nema-type1","nema-type1-load-side"]},"selection":{"text":"Ask the electrician to identify the intended connection side and device ratings; a Type 1 label does not restrict it to the supply side.","facts":["nema-type1","nema-type1-load-side","nema-vpr"]},"life":{"text":"NIST (2001): exceptional stress can end protection prematurely; no fixed years stated.","facts":["nist-life"]}}},{"option":"type-2","label":"Type 2 panel SPD","cells":{"place":{"text":"Permanently connected on the load side of the service disconnect.","facts":["nema-type2"]},"selection":{"text":"Specify the load-side panel location and short interconnecting leads, alongside the proposed VPR and discharge-current ratings.","facts":["nema-type2","nema-leads","nema-vpr","nema-levels"]},"life":{"text":"NIST (2001): exceptional stress can end protection prematurely; no fixed years stated.","facts":["nist-life"]}}},{"option":"type-3-plug","label":"Type 3 plug-in or cord-connected SPD","cells":{"place":{"text":"Cord-connected or direct plug-in; Type 3 placement uses at least 10 meters (30 feet) of conductor from the panel.","facts":["ul-plug","nema-distance"]},"selection":{"text":"Name the equipment connection and document the Type 3 conductor distance; compare VPR rather than treating the type number as a performance score.","facts":["ul-plug","nema-distance","nema-vpr"]},"life":{"text":"NIST (2001): exceptional stress can end protection prematurely; no fixed years stated.","facts":["nist-life"]}}},{"option":"type-3-receptacle","label":"Type 3 receptacle SPD","cells":{"place":{"text":"Surge protection at a receptacle; still a Type 3 device, with its placement requirement.","facts":["ul-receptacle","nema-distance"]},"selection":{"text":"Specify the receptacle form and intended equipment location; the Type 3 conductor-distance condition still matters.","facts":["ul-receptacle","nema-distance"]},"life":{"text":"NIST (2001): exceptional stress can end protection prematurely; no fixed years stated.","facts":["nist-life"]}}}]},{"caption":"What do surge protector ratings mean?","columns":[{"key":"meaning","label":"What the number describes","source_line":"NEMA FAQs (undated); NIST SP 960-6 (2001); read 2026-11-09."}],"rows":[{"option":"vpr","label":"Voltage protection rating","cells":{"meaning":{"text":"VPR uses a 6 kV, 3 kA test waveform; standard rating values include 330, 400 and 500.","facts":["nema-vpr-test","nema-vpr"]}}},{"option":"in","label":"Nominal discharge current","cells":{"meaning":{"text":"NEMA lists 3kA, 5kA, 10kA and 20kA levels; the definition includes remaining functional after 15 surges.","facts":["nema-levels","nema-in"]}}},{"option":"mcov","label":"Maximum continuous operating voltage","cells":{"meaning":{"text":"NEMA describes MCOV as typically 15-25% above nominal system voltage; match the device to the electrical system.","facts":["nema-mcov"]}}},{"option":"joules","label":"Energy capacity","cells":{"meaning":{"text":"NIST’s 2001 guide described about 100 to 1000 joules or more; a historical explanation, not a present-day minimum.","facts":["nist-joules"]}}}]}]