A subpanel is an additional electrical distribution panel fed from a breaker in the main panel. InterNACHI describes a typical 4-wire feeder with two hot conductors, a neutral and a ground. Its neutral and ground stay separate, so the installation scope needs to address their separate connections.

InstaBids is an AI-run marketplace for homeowners and property managers: describe a home job once, by chat or through your own AI assistant, add photos, and get multiple written quotes on the same scope, compared apples to apples, with no phone calls or home visits before you pick.

By . Updated

What this means for your home project

  1. Read the circuit labels without removing the panel cover; list unidentified circuits for the electrician to label. Source: City of Palo Alto, read 2026-11-05.
  2. Request a written feeder specification naming the conductor size and the corresponding overcurrent protection device. Source: Los Angeles County Public Works, read 2026-11-05.
  3. Gather permit records for any existing underground conduit; ask the installer whether the scope includes exposing it for inspection. Source: Los Angeles County Public Works, read 2026-11-05.
InstaBids assistantAI · builds your written scope with you

What subpanel job do you need done in your home? Describe it once to start your written scope.

Start from a common job
You choose who gets your number
Or send it from your own AIChatGPTClaudeGrokGeminiMore ways
  1. Describe it onceBy chat, or through your own AI assistant, and add photos.
  2. Post it and send itContractors bid in writing on that scope.
  3. Compare line by lineEvery quote is written against the same scope.
  4. You chooseContact details stay hidden until you pick and they confirm.
InstaBids

For your AI assistant

MCP connector · REST API · plain HTML

Hand any of these to your assistant and it can help you write this job's request; you send the request yourself. What you type in the job box above goes into the prompt these buttons carry. The connector asks you to sign in to your InstaBids account the first time.

  • MCP connector URLhttps://instabids.ai/api/agent/mcp
  • Agent API (OpenAPI)https://instabids.ai/openapi.json
  • Start-request linkhttps://instabids.ai/intake?from=glossary-subpanel&page_type=glossary&job=Plan+a+subpanel+installation+with+a+feeder+specification+and+load+calculation&utm_source=us&utm_medium=page&utm_campaign=glossary
Open it in your assistantAdd InstaBids as a connector

Every page is plain HTML. Steps for every assistant: add to your assistant.

Is the neutral bus isolated from the panel enclosure?

Use InterNACHI (read 2026-11-05) to compare the electrician’s proposed subpanel connections with the connections at the main disconnect. “In this subpanel, the neutral conductor is the insulated neutral wire on the right, and it is connected to the neutral busbar, which must be isolated from the enclosure cabinet.” (source) “A subpanel must be equipped with separate ground and neutral bars, but only the ground bar should be bonded to the panel enclosure.” (source) “They should not be connected to the same busbar the way they are at the main disconnect.” (source)

What size subpanel do you recommend?

Use Los Angeles County’s ADU guidance (read 2026-11-05), CEC Section 310.12, to request a feeder specification supported by calculations. “Feeder conductors between structures and panels shall be properly sized to the corresponding overcurrent protection device.” (source) Las Vegas’s residential form (read 2026-11-05) separately states: “If there is a subpanel, a separate Electrical Load Calculation is required.” (source)

What are the guidelines for clearance around a subpanel?

Palo Alto’s 2018 inspection guide (read 2026-11-05), under its 2016 codes, gives a local example for assessing the proposed location. “Provide the following working clearances: 36” in depth, 30” in width, and 6’-6” in height.” (source) Los Angeles County’s ADU guide (read 2026-11-05) adds: “The equipment doors are additionally required to open at least 90 degrees.” (source)

What additional costs might come up during installation?

Los Angeles County’s ADU guide (read 2026-11-05) identifies an inspection-access issue to clarify before agreeing to underground feeder work. “Existing underground conduit without valid permit records may need to be exposed entirely for inspection.” (source)

Does a detached garage need its own ground rod?

Los Angeles County’s ADU guidance (read 2026-11-05), CEC Article 250, makes the grounding question depend on the building’s circuit arrangement. “Buildings with more than one multi-wire branch circuit (i.e., more than 2 branch circuits) require a complete grounding electrode system.” (source) “If the supplemental electrode is a ground rod, then there should be two ground rods spaced at least 6 feet apart.” (source) “A grounding electrode system may need to be installed at both the building with the electrical service and at the detached structure with a subpanel.” (source)

Sources